To begin the Verifying the Quality of Coating Application quiz, click the Start Quiz button.
To skip a question to answer prior to submitting your answers, click the Review question button.
Answer all questions, click Quiz Summary button to ensure all questions have been answered, then click the Finish Quiz button.
To pass, you must receive a score of at least 80%. You can retake the quiz, if needed.
Verifying the Quality of Coating Application Quiz
Quiz Summary
0 of 36 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 36 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 36
1. Question
Which of the following ambient conditions should be measured prior to mixing and application of coatings?
CorrectIncorrect -
Question 2 of 36
2. Question
What can occur if coatings are applied outside of the specified temperature ranges?
CorrectIncorrect -
Question 3 of 36
3. Question
What is dew point temperature?
CorrectIncorrect -
Question 4 of 36
4. Question
What is the minimum delta between the surface temperature and dew point temperature for painting work to begin or continue?
CorrectIncorrect -
Question 5 of 36
5. Question
Where should ambient conditions be assessed?
CorrectIncorrect -
Question 6 of 36
6. Question
According to ASTM E337, when using a whirling (sling) psychrometer, the web bulb temperature is considered stable when:
CorrectIncorrect -
Question 7 of 36
7. Question
What two values are used to look-up relative humidity & dew point temperature when using the US Weather Bureau psychrometric charts?
CorrectIncorrect -
Question 8 of 36
8. Question
True or False: Digital (electronic) psychrometers do not require an acclimation period.
CorrectIncorrect -
Question 9 of 36
9. Question
What is the most common procedure for verifying the accuracy of thermometers?
CorrectIncorrect -
Question 10 of 36
10. Question
What is the frequency of calibration recommended by most manufacturers of digital psychrometers?
CorrectIncorrect -
Question 11 of 36
11. Question
What two characteristics of a mixed, multi-component coating are based on the temperature of the material?
CorrectIncorrect -
Question 12 of 36
12. Question
What instruments are used to measure paint temperature?
CorrectIncorrect -
Question 13 of 36
13. Question
What happens to the volume solids content of a coating when it is thinned?
CorrectIncorrect -
Question 14 of 36
14. Question
What is the purpose of measuring the wet film thickness during application of a coating?
CorrectIncorrect -
Question 15 of 36
15. Question
What three values are used to calculate the target wet film thickness (select 3).
CorrectIncorrect -
Question 16 of 36
16. Question
Calculate the target wet film thickness using the following information:
Specified dry film thickness: 8 mils
Volume solids content of the coating: 72%
CorrectIncorrect -
Question 17 of 36
17. Question
Calculate the target wet film thickness using the following information:
Specified dry film thickness: 6 mils
Volume solids content of the coating: 85%
Thinner added: 15%
CorrectIncorrect -
Question 18 of 36
18. Question
Using the wet-to-dry ratio method, what is the “practical” volume solids content of the coating that was thinned 5%, applied at 10 mils WFT and measures 6 mils DFT?
CorrectIncorrect -
Question 19 of 36
19. Question
When using a notch-type wet film thickness gage, the wet film thickness is considered:
CorrectIncorrect -
Question 20 of 36
20. Question
What is the primary difference between ASTM D7091 and SSPC-PA 2 standards for coating thickness measurement?
CorrectIncorrect -
Question 21 of 36
21. Question
How does a magnetic pull-off gage measure coating thickness?
CorrectIncorrect -
Question 22 of 36
22. Question
Which of the following cannot be performed by the gage operator in the field?
CorrectIncorrect -
Question 23 of 36
23. Question
What is the frequency of calibration of dry film thickness gages recommended by most manufacturers?
CorrectIncorrect -
Question 24 of 36
24. Question
What is the recommended frequency for verifying the accuracy of dry film thickness gages?
CorrectIncorrect -
Question 25 of 36
25. Question
Which of the following best describes a two-point accuracy verification?
CorrectIncorrect -
Question 26 of 36
26. Question
Calculate the combined tolerance of a gage with 3% accuracy when using traceable coated standards with 5% accuracy.
CorrectIncorrect -
Question 27 of 36
27. Question
How can an individual determine the effect of the base metal on coating thickness measurements?
CorrectIncorrect -
Question 28 of 36
28. Question
True or False: Base metal reading and surface profile are identical.
CorrectIncorrect -
Question 29 of 36
29. Question
According to ASTM D7091 and SSPC-PA 2, which of the following is used to verify the accuracy of a dry film thickness gage?
CorrectIncorrect -
Question 30 of 36
30. Question
According to ASTM D7091 and SSPC-PA 2, which of the following is used to in conjunction with an electronic dry film thickness gage to compensate for surface roughness?
CorrectIncorrect -
Question 31 of 36
31. Question
What type of probe is best when measuring coating thickness along edges?
CorrectIncorrect -
Question 32 of 36
32. Question
According to SSPC-PA 2, a spot measurement is:
CorrectIncorrect -
Question 33 of 36
33. Question
According to SSPC-PA 2, the minimum number of gage readings to obtain to generate a spot measurement is:
CorrectIncorrect -
Question 34 of 36
34. Question
According to SSPC-PA 2, the number of spot measurements averaged together to create an area measurement is:
CorrectIncorrect -
Question 35 of 36
35. Question
According to SSPC-PA 2, if the total area coated during the work shift was 4,500 square feet, how many areas must be assessed for coating thickness?
CorrectIncorrect -
Question 36 of 36
36. Question
If the pipe spool diameter is 20 inches, how many circumferential spot measurements are obtained?
CorrectIncorrect