Quiz Summary
0 of 25 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 25 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 25
1. Question
Corrosion can only occur when the following elements are present:
CorrectIncorrect -
Question 2 of 25
2. Question
Corrosion occurs at the:
CorrectIncorrect -
Question 3 of 25
3. Question
The anode, cathode, electrolyte and connection between the anode and cathode is known as:
CorrectIncorrect -
Question 4 of 25
4. Question
The surface of carbon steel already contains three elements needed for corrosion; the missing element is:
CorrectIncorrect -
Question 5 of 25
5. Question
Convert 350 microns to mils
CorrectIncorrect -
Question 6 of 25
6. Question
Why is the removal of mill scale from carbon steel important?
CorrectIncorrect -
Question 7 of 25
7. Question
An inspector representing California Water Service Group is fulfilling the role of a:
CorrectIncorrect -
Question 8 of 25
8. Question
Which of the following organizations prepares test methods but does not provide acceptance criteria?
CorrectIncorrect -
Question 9 of 25
9. Question
The acceptance criterion for surface profile depth is established by:
CorrectIncorrect -
Question 10 of 25
10. Question
The depth of an anchor pattern or surface profile is primarily determined by the:
CorrectIncorrect -
Question 11 of 25
11. Question
Grease and oil left on the surface of a substrate can:
CorrectIncorrect -
Question 12 of 25
12. Question
According to ASTM D4417, if the replica tape method is used to measure surface profile, how many readings are obtained per area?
CorrectIncorrect -
Question 13 of 25
13. Question
Which of the following is an “indirect requirement” of the SSPC surface cleanliness standards?
CorrectIncorrect -
Question 14 of 25
14. Question
SSPC SP11, “Power Tool Cleaning to Bare Metal:”
CorrectIncorrect -
Question 15 of 25
15. Question
A “Near-white Metal Blast” or SSPC-SP10, allows __________to remain on the surface.
CorrectIncorrect -
Question 16 of 25
16. Question
Prior to final surface preparation, the most important relationship to assess when measuring and recording ambient conditions is:
CorrectIncorrect -
Question 17 of 25
17. Question
If the compressed air used during abrasive blast cleaning contains oil or water, it can:
CorrectIncorrect -
Question 18 of 25
18. Question
The photographic guides developed by SSPC to aid in the visual assessment of surface cleanliness were designed to be used:
CorrectIncorrect -
Question 19 of 25
19. Question
Surface profile or the anchor pattern:
CorrectIncorrect -
Question 20 of 25
20. Question
A “Commercial Blast” or SSPC-SP6, allows __________to remain on the surface.
CorrectIncorrect -
Question 21 of 25
21. Question
All of the following can be used to determine the surface profile on concrete except
CorrectIncorrect -
Question 22 of 25
22. Question
SSPC-SP7, Brush-off Blast Cleaning:
CorrectIncorrect -
Question 23 of 25
23. Question
Which of the following tests are invoked by all three of the SSPC Abrasive Specifications (AB1, AB2 and AB3)?
CorrectIncorrect -
Question 24 of 25
24. Question
If Testex Coarse replica tape is used to measure the surface profile and the reading is between 1.5-2.5 mils, what must be done?
CorrectIncorrect -
Question 25 of 25
25. Question
The Testex micrometer was set on “0.” When the tape was inserted, the micrometer read 4.6 mils. The actual surface profile is:
CorrectIncorrect