Address

145 Enterprise Drive Pittsburgh, PA 15275

Call Us Now

1-800-245-6379

Email

info@kta.com

Menu

Chaz Sztroin

coating failure analysis

Coating Failure Analysis Series – Part 6 – Laboratory Forensic Analysis

This is a six-part video series that demonstrates the field and laboratory methods that were used to determine why a new coating system applied to a previously painted concrete floor had failed. Each part is standalone, addressing a different aspect of the evaluation, but when viewed in order, they present a systematic step-by-step process for …

Coating Failure Analysis Series – Part 6 – Laboratory Forensic Analysis Read More »

field microscopic examination

Coating Failure Analysis Learning Series – Part 5 – Field Microscopic Examination

Welcome to the KTA Coating Failure Analysis Video Learning Series! This is a six-part video series that demonstrates the field and laboratory methods that were used to determine why a new coating system applied to a previously painted concrete floor had failed. Each part is standalone, addressing a different aspect of the evaluation, but when viewed …

Coating Failure Analysis Learning Series – Part 5 – Field Microscopic Examination Read More »

tooke gage

Coating Failure Analysis Learning Series – Part 3 – Tooke Gage

Welcome to the KTA Coating Failure Analysis Video Learning Series! This is a six-part video series that demonstrates the field and laboratory methods that were used to determine why a new coating system applied to a previously painted concrete floor had failed. Each part is standalone, addressing a different aspect of the evaluation, but when viewed …

Coating Failure Analysis Learning Series – Part 3 – Tooke Gage Read More »

field adhesion testing

Coating Failure Analysis Learning Series – Part 4 – Field Adhesion Testing – Knife & Tensile

Welcome to the KTA Coating Failure Analysis Video Learning Series! This is a six-part video series that demonstrates the field and laboratory methods that were used to determine why a new coating system applied to a previously painted concrete floor had failed. Each part is standalone, addressing a different aspect of the evaluation, but when viewed …

Coating Failure Analysis Learning Series – Part 4 – Field Adhesion Testing – Knife & Tensile Read More »

field moisture detection

Coating Failure Analysis Learning Series – Part 2 – Field Moisture Detection

Welcome to the KTA Coating Failure Analysis Video Learning Series! This is a six-part video series that demonstrates the field and laboratory methods that were used to determine why a new coating system applied to a previously painted concrete floor had failed. Each part is standalone, addressing a different aspect of the evaluation, but when viewed …

Coating Failure Analysis Learning Series – Part 2 – Field Moisture Detection Read More »

coating failure analysis

Coating Failure Analysis Learning Series – Part 1 of 6

Welcome to the KTA Coating Failure Analysis Video Learning Series! This is a six-part video series that demonstrates the field and laboratory methods that were used to determine why a new coating system applied to a previously painted concrete floor had failed. Each part is standalone, addressing a different aspect of the evaluation, but when viewed …

Coating Failure Analysis Learning Series – Part 1 of 6 Read More »

positive material identification

Positive Material Identification (PMI)

Positive Material Identification has become a convenient and reliable way to determine the alloy compositions of materials. One of the greatest advantages of using a PMI unit is its portability, weighing approximately 5-8 lbs. with the battery loaded into the unit, it can be easily transported and used in confined areas or field applications. With the …

Positive Material Identification (PMI) Read More »

Type 2 dry film thickness gauge

[VIDEO] Verification of Accuracy Of Type 2 Gauges According To SSPC PA-2 & ASTM D7091

Type 2 Dry Film Thickness Gauge – Verification of Accuracy [embedyt] http://www.youtube.com/watch?v=i5WucAibO9s[/embedyt] Join KTAGage’s Matt Fajt for an explanation on Verification of Accuracy in relation to Type 2 gauges as it relates to SSPC PA-2 and ASTM D7091. For more information, or to view our product listings, please visit www.ktagage.com

KTA-Tator, Inc. Announces Promotions

Press Release KTA-Tator, Inc. Announces Promotions With an eye on the future KTA implements succession plan Pittsburgh, May 19, 2016: KTA-Tator, Inc., a 67-year-old coatings and steel inspection, testing, and consulting firm announces promotions in several key positions. “CEO Dan  Adley and I are honored to publically recognize the critical roles that Bill Corbett, Cindy …

KTA-Tator, Inc. Announces Promotions Read More »

sspc vis-1

KTA Lunch N’ Learn Webinar: Understanding SSPC Abrasive Blast Cleaning Standards and SSPC-VIS 1

Learning Objectives for this SSPC Abrasive Blast Cleaning Standards Webinar include: -Understand the written SSPC abrasive blast cleaning standards -Understand the use of SSPC-VIS 1, Guide and Reference Photographs for Steel Surfaces Prepared by Dry Abrasive Blast Cleaning     “Understanding SSPC Abrasive Blast Cleaning Standards and SSPC-VIS 1” is a Lunch N’ Learn Webinar …

KTA Lunch N’ Learn Webinar: Understanding SSPC Abrasive Blast Cleaning Standards and SSPC-VIS 1 Read More »